⚠️ Important Safety Notice
This procedure should only be carried out by qualified maintenance personnel. MachineMetrics takes no responsibility for any errors, damage, or unintended behavior resulting from enabling Parameter Write Enable (PWE) or editing parameters. Proceed with caution.
Prerequisite: Machine State
-
Put the CNC into either:
-
MDI mode, or
-
Emergency Stop (E-Stop) state
(This ensures safety while making parameter changes.)
-
Steps to Enable Parameter Write
-
Access the Setting Screen
-
Press the
SETTING
function key, or: -
Press the function key once, then press the
[SETTING]
soft key. -
This opens the first page of the setting screen.
-
-
Navigate to "PARAMETER WRITE"
-
Use the cursor keys to move the highlight to the
PARAMETER WRITE
setting.
-
-
Enable Parameter Write
-
Press the
(OPRT)
soft key to bring up operation options. -
Either:
-
Press the
[ON:1]
soft key, or -
Enter
1
and press theINPUT
key.
-
-
-
Confirmation
-
Once enabled, an alarm like SW0100: PARAMETER WRITE ENABLE appears.
-
This is normal and indicates parameters are now editable.
-
-
Disable When Done
-
After finishing your parameter edits, repeat the steps and set
PARAMETER WRITE = 0
. -
This will clear the SW0100 alarm and lock parameters from further changes.
Comments
0 comments
Please sign in to leave a comment.