How to enable part count in single mode on Citizen M700 series controls

1. Press the MAINT hard key.

2. Press the I/F diag soft key.

3. Type 1001//M then Press INPUT.

5. Press the PARAM hard key.

6. Scroll to the right with the arrow keys until you see Menu Sel.

7. Press the Menu Sel softkey until parameter 6401 is visible.

8. Press the BIT SELECT soft key.

9. Select parameter 6401.

10. Change the third from the right number from 0 to 1. (Ex. 01001000 -> 01001100).

11. Press the INPUT hard key.

12. Reboot the machine.

 